Shower Facilities / Alternative Roll-in Shower

Alternative Roll-in Shower

An alternative roll-in shower configuration is permitted with the following specifications:

Dimensional Requirements

Dimension Metric Imperial
Minimum total length 1.50 M 60 IN.
Minimum interior depth 0.90 M 36 IN.
Entry width 0.60 M 24 IN.
Overall width 0.90 M 36 IN.
Clearance 0.40 M 10 IN.

Equipment Specifications

Component Metric Imperial
Grab bar length 1.05 M 42 IN.
Grab bar mounting Mounted on wall

Required Features

  • Floor drain: Centrally located
  • Seat: Foldable seat positioned at side
  • Grab bar: 1.05 M (42 IN.) mounted on wall

This diagram illustrates the specific requirements of these regulations and is intended only as an aid for building design and construction.

For general bathing facility requirements, see Bathing and Toilet Facilities - General Requirements.