Alternative Roll-in Shower
An alternative roll-in shower configuration is permitted with the following specifications:
Dimensional Requirements
| Dimension | Metric | Imperial |
|---|---|---|
| Minimum total length | 1.50 M | 60 IN. |
| Minimum interior depth | 0.90 M | 36 IN. |
| Entry width | 0.60 M | 24 IN. |
| Overall width | 0.90 M | 36 IN. |
| Clearance | 0.40 M | 10 IN. |
Equipment Specifications
| Component | Metric | Imperial |
|---|---|---|
| Grab bar length | 1.05 M | 42 IN. |
| Grab bar mounting | Mounted on wall | — |
Required Features
- Floor drain: Centrally located
- Seat: Foldable seat positioned at side
- Grab bar: 1.05 M (42 IN.) mounted on wall
This diagram illustrates the specific requirements of these regulations and is intended only as an aid for building design and construction.